Guides · BOM sourcing

How to Check a TPS5430 Catch Diode Before Substitution

Check reverse voltage, current and thermal conditions before accepting a proposed TPS5430 catch-diode replacement.

· StockWake team · Source: Original content by StockWake. Please credit StockWake when republishing.

Schottky-diode-on-a-buck-converter-board-for-TPS5430-review

A 3 A rating alone does not make a Schottky diode a safe replacement for the TPS5430 catch diode. You must check the reverse voltage, average and peak current, forward loss, temperature limits, and mounting conditions against your actual circuit. A higher voltage rating can give you more reverse-voltage headroom, but it may also increase forward loss. It does not, by itself, approve the substitution.

Lock Down the Circuit and the Actual Change

This guide covers the standard TPS5430 in a positive-output, nonsynchronous buck circuit. Its external diode connects between PH and GND. Do not carry these checks unchanged into an inverting converter.

For TPS5430 Schottky diode selection, first record the input range, output voltage, maximum load, inductor and tolerance, switching-frequency limits, ambient range, and PCB revision. A nominal input label does not describe the highest voltage the diode will actually see.

Check Every Electrical Stress Point

TPS5430 Catch Diode Reverse Voltage

TI SLVS632L Rev L, Section 7.2.1.2.7, requires a reverse-voltage rating above VIN(MAX) + 0.5 V. At a stated maximum input of 36 V, that rule requires more than 36.5 V. Do not turn the remaining voltage headroom into an assumed allowance for every board.

TPS5430 Catch Diode Peak Current

TI's criterion is above the maximum output current plus half the peak-to-peak inductor ripple. The catch diode carries the inductor current during the off interval. Its repetitive peak therefore differs from both the load-current average and a nonrepetitive surge rating.

Match Each Stress to Its Relevant Corner

Scroll sideways to see the whole table

Check

Relevant Corner

Evidence to Retain

Reverse voltage

Maximum input, including relevant transients and ringing

TI's VIN(MAX) + 0.5 V criterion and the actual voltage envelope

Average current

Maximum load and long diode conduction interval

Duty ratio, current waveform, and the diode's stated rating conditions

Repetitive peak

Maximum load with the applicable minimum inductance and frequency

Ripple calculation or waveform and applicable diode capability

Temperature

Hot ambient and the actual cooling arrangement

Package, copper, mounting, and junction-temperature assessment

Compare Complete Ordering Codes and Thermal Conditions

TI names B340A in its reference design. That does not approve it for every TPS5430 circuit. The comparison below uses complete orderable examples from the B3XXA-13-F ordering row in Diodes DS30891 Rev 20-2 (dated October 2026).

Compare the Published Ratings Under Their Stated Conditions

Scroll sideways to see the whole table

Item

B340A-13-F

B360A-13-F

Condition or Limit

VRRM

40 V

60 V

Published repetitive reverse-voltage rating

Average rectified current

3.0 A

3.0 A

TT = 100°C; the maximum-ratings section states 60 Hz half-wave conditions

Maximum Vf

0.50 V

0.70 V

Electrical-characteristics table: IF = 3.0 A, TA = 25°C

Nonrepetitive IFSM

80 A

80 A

8.3 ms single half-sine superimposed on rated load

Do not read the 3 A row as an unconditional high-frequency PCB rating. The 80 A surge row does not establish an allowable repetitive switching peak. If that capability remains unresolved, obtain applicable manufacturer information before accepting the change.

Here, TT is terminal temperature and TA is ambient temperature. A 3 A rating at controlled TT does not establish the same current at hot ambient. The published −55°C to 150°C range is a junction-temperature range, not an ambient-temperature guarantee. The sheet's typical junction-to-ambient thermal resistances also depend on its stated PCB and copper conditions. Keep the actual mounting and cooling in the thermal review.

The 0.50 V and 0.70 V values are maximum limits at the same stated test point. They are not predictions of either diode's loss on your board. Assess Vf and current over the actual operating waveform and temperature. Reverse leakage also contributes loss.

Consider a fictional screening case: 36 V input, 5 V output, 3 A load, 15 µH inductance, and 500 kHz. An ideal continuous-conduction calculation gives D ≈ 0.139, average diode current ≈ 2.58 A, ripple ≈ 0.574 A peak-to-peak, and peak current ≈ 3.29 A. These are nominal model results at the high-input point, not bounded worst-case currents.

In this ideal model, D is the high-side duty ratio, approximately VOUT/VIN. Average diode current is IOUT × (1 − D). Minimum inductance and switching frequency still need their own values for the peak-current review. No board was built or tested for this example.

Check the complete code on the quotation and package label. Our marking and full-part-number guide explains why a short body marking does not establish that code.

Preserve the Approval and Purchase Evidence

Record the original and proposed complete codes against the affected BOM and PCB revisions. Keep the operating limits, source-document versions, calculations, remaining checks, and the reviewer's decision and restrictions together. Use the approved-alternative recording method when that decision enters a sourcing request.

Separate that engineering decision from the evidence for the offered material. A package inspection cannot establish a thermal margin or repeated-current capability. Our document-scope comparison helps distinguish what the offered evidence actually covers.

FAQ

Can Any 3 A Schottky Replace the Reference Diode?

No. Match reverse voltage, average and repetitive current conditions, forward losses, temperature, package, and polarity to the actual circuit.

Does an 80 A Surge Rating Cover the Switching Peak?

No. The cited 80 A value is a nonrepetitive 8.3 ms half-sine rating. It does not establish capability for the repeated peaks in the converter.

What Reverse Voltage Does the TPS5430 Catch Diode Need?

TI specifies a rating above VIN(MAX) + 0.5 V. Do not select from the nominal input alone or assume a fixed remaining margin suits every layout.

Does the Same SMA Package Establish a Fit?

No. Compare the actual package drawing, cathode orientation, land pattern, and mounting conditions for the supplied ordering codes.

What Should Purchasing Keep After Approval?

Keep both complete codes, the affected BOM and PCB revisions, source-document versions, supporting calculations or applicable results, the approver, and any restrictions.

Keep the Substitution Decision Specific

Record which limits are met, which checks remain open, and who owns the next check. Keep a higher voltage rating or a matching 3 A label from standing in for that decision.

Related guides

Keep reading

  • BOM sourcing

    Compare how long usable stock lasts with the time to a workable solution, then assign the next action.

    How to Prioritize Component Obsolescence Risks in a BOM

    To prioritize obsolescence risks in a BOM, start with the parts that could run short before a workable solution is ready. Check how long your usable stock can cover demand, when more stock or an approved alternative could actually be used, and what the shortage would interrupt. Give each open line an owner and a date for the next decision. The first line engineering needs to review may differ from the first order purchasing needs to place.

  • BOM sourcing

    Engineer-reviewing-an-obsolescence-plan-beside-a-control-board

    How to Build an Electronic Component Obsolescence Plan Before an EOL Notice

    Build a dated component risk register before an EOL notice. Separate official status from supply signals and assign owners, review dates and escalation triggers.

  • BOM sourcing

    One Quote for a BOM With EOL and Shortage Parts

    How to prepare a BOM with end-of-life and shortage lines so it can be quoted in one pass, and what the quotation should state for each line.

All guides →